Copyright © 2018 Zhuhai Sinopak Electric Ltd.  Powered by www.300.cn   

粤ICP备15110204号-1

Scan the qr code

Product center

Zhuhai Sinopak Electric Ltd

Add:  Office 801,  No. 1316 Caixia Street, Hengqin, Zhuhai City, Guangdong Province, China

Tel:  +86-756-7755124

Wechat&WhatsApp:  +86-13928032657

Website:  www.sinopakelectric.com

 

Contact us

Medium Voltage Magnetically Controlled Soft Starter

Medium Voltage Magnetically Controlled Soft Starter

AC motors are widely applied in every field of national economic, when the motor starts directly, there are lots of problems, such as big starting current
没有此类产品
111
Description

Medium Voltage Magnetically Controlled Soft Starter

AC motors are widely applied in every field of national economic, when the motor starts directly, there are lots of problems, such as big starting current, violent impact on power grid and mechanical equipment, short service life of motor, which will generate high maintenance cost every year. Sinopak High voltage Magnetically controlled soft starter can reduce the voltage drop caused by direct starting motor, it will not affect the normal run of other equipment, and meanwhile, it can reduce the impact current of motor,because impact current will cause temperature rise of the motor, which result in motor insulation damage etc.

Sinopak High voltage magnetically controlled soft starter can start and stop at any time and improve working efficiency. 

 

 
 
 
 
 
 
 
 
 
 
 

Principle of Magnetic control Soft Starter

A high-voltage magnetic controlled soft starter is composed of inlet wires, switch and medium-voltage controlled reactor, motor and its load. A fail-safe secondary control system is composed of controller, three-phase full wave rectifier and high/low-voltage dual isolators. 

 
 
 
 
 

In the system of high-voltage magnetic control soft starter, closed-loop current control is achieved by acquiring primary loop current to adjust the low-voltage control coil so as to change the reactance value of high tension loop of the reactor, such that the motor may be started up smoothly.

 

 

 

Technical specification for Magnetic controlled reactor

 

Rated voltage

3kV~11kV

Power range

250kW~30000KW

Rated frequency

50Hz

Starting current

1.5-3.5In

Phase

3Phases

Insulation temperature

F Class

Environment temperature:

≤450C

Flux leakage

Free of flux leakage

Motor start time

0~60s

Continuous starting times

4 Times/H

Cooling

Natural air cooling

Environment class

E0

Noise level

<70DB

Communication

Modbus

 

未找到相应参数组,请于后台属性模板中添加